For Samsung Refrigerator Compressor Overload Protector (Part Number: OEM13004352)

1 Answer

Sammy,

Unfortunately, we do not have an owner's manual for Samsung but you may be able to find it on the manufacturer's website. If the unit showing OF OF on the display then you should be able to turn it back on press Energy Saver Button and Freezer/Hold 3 sec for Power Freeze Button simultaneously for 3 seconds until an
alarm sound is heard.

Read More...

1 Answer

Hello Willowdale,
You can remove the overload from the compressor and use a test meter from the part that plugs onto the compressor to the part where the wire connects to the overload. This should read continuity with no resistance.

Read More...
Albert for Model Number Samsung SR-L62

The fridge/freezer combination has an intermittent failure. It may run and cool normally for a number of cycles (several hours) than it stops running and won't start again, so it slowly warms up. When I pull the main plug and put it back in, the fridge restarts and again it runs for a couple of cycles and cools normally. After a while the problem starts all over again. I already checked the sensors, they seem te be okay. I suspected the compressor relay to be bad (the white one on the main board), I replaced it; no success. Finally, I guess the overload protector may be the culprit. Though I have no idea where I can buy a spare. I live in Belgium, Europe. I just wonder if this behavior of running normally, stopping and running again after pulling the mains, be caused by a bad overload protect? Thank you for your kind reply.

1 Answer

Hello Albert,
unfortunately, we have no technical/parts information on international models. If only the compressor stops and the fans are still running then yes it may be compressor related, but if all operation stops, meaning no fans or compressor then there is a control problem.

Read More...
John for Model Number RFG238AARS/XAA

Samsung French door frig stopped cooling and freezing. There are no error codes on the self diagnostic tests and the red LED light on the control board in the rear is not flashing any codes (always been a solid red). The cooling fan on the compressor runs but the compressor doesn't kick in. I replaced the compressor relay protector switch (I should have first tested continuity before ordering the part from APP) on the compressor but when powered up, after a few seconds for booting up (and several clicks from the control board or circuit board) the compressor seemed to want to kick on for a few seconds and then quit again. I am consigned to let it die a dignified death now but wanted your final opinion on anything else I may have missed before casting it into the appliance graveyard. We have absolutely loved this frig but it is of an age that it no longer owes us anything. Much appreciated!

1 Answer

John, based on the information provided, it sounds like the inverter board DA41-00614F is not closing the relays properly. As the compressor is attempting to start, but will not and the inverter is not flashing an error, this is what identifies the inverter as being the issue. However, due to the on and off start of the compressor, it is possible that the compressor may have been impacted by the control failure as it is not good on a compressor to kick on and off repeatedly (with short pauses in between starts).

Read More...
John for Model Number RFG238AARS/XAA

Frig quit cooling (freezer and frig). The compressor is not kicking on nor can I force it to run with the fast cool/freeze option. I pulled the cover off to expose the PC board and the red LED was solid red (not flashing). No error codes are indicated on the self check on the front control panel. I have ordered a Compressor Overload Protector from appliancepartspro.com after watching the replacement video. The video mentioned that the two wires feeding the COP were just to complete a circuit so could go back in any order. I am just wondering if I could check the COP by jumping these two wires (by-passing the COP) so as to see if the problem is in fact the COP or whether I have a compressor issue. Also, I noticed that I can hear a rattling when I shake the COP. Does this mean it is indeed defective?

1 Answer

John, the overload protector can be tested for continuity between the terminals. If there is not continuity, then the overload has failed. It is not recommended that the overload is bypassed as it can inadvertently cause damage to the control board if there is too much amperage passing through.

Read More...
Miguel for Model Number RF268ABRS/XAA-0000

I have a Samsung Fridge that stopped cooling (Fridge and Freezer). When I looked at the back of the fridge, it was flashing on the PCB board two flashes which said it was the PCB board. So I ordered the PCB board and replaced it (Order #10712648). The PCB board then started to flash 4 times, which said it was the compressor. I thought it might be the compressor overload protector, so I ordered that and replaced it (Order #10751450). The PCB board is still flashing 4 red flashes, which says it is the compressor. I hear the compressor start for 2 seconds at a time and then stop, more or less like it used to when the compressor was working, but I can't hear the compressor working and it is cold. The fridge still won't get cool. Any help you could give me I would appreciate. Thanks.

1 Answer

Miguel, the four blinks is going to indicate a locked compressor. The compressor windings can be tested directly at the compressor from pin 1 to2, pin 1 to 3, then pin 2 to 3. Each test should measure 10 Ohms of resistance. However, when the controls sense a locked compressor, they will not try to start the compressor until the system is powered off for a minimum of ten minutes.

Read More...
Heather for Model Number RF260BEAESR

My freezer is working fine, but I notices the fridge wasn't as cool as it should be and I could see frost in the back of the fridge. Took off the inside back cover, defrosted the coils and the fan. Was told the fan once again was now working. 2 days later the fridge is a little colder... but not as cold as it used to be or what I have it set at. Freezer is still working, however, I still do not hear the compressor or the fan. I realized I have not heard the typical fridge noises in a while. Again, only the freezer is working just fine. Could this be a relay part issue or something else? I would think if the compressor was bad that the freezer would also not be working?

1 Answer

Heather, You are correct, " I would think if the compressor was bad that the freezer would also not be working" If the compressor was "bad" the freezer would also have a warm temperature. Your refrigerator has two evaporators (one in the refrigerator and one in the freezer, but only one compressor. At this point, based on your description, you'll need to carefully remove the rear panel/air tunnels assembly from the back of the refrigerator, and check the defrost heater, sensor and thermostat, and wiring.

Read More...
Shane for Model Number RF4287HARS/XAA

Refrigerator quit a couple of months ago so I cleaned the condenser coils and it began working again. It quit again a couple of weeks ago so I replaced the compressor overload protector which I purchased from you folks. The compressor and condenser fan motor are running and the refrigerator is cooling to 38 F but the freezer is still room temp. I checked the evaporator fan motor and it runs for a little while when I plug the refrigerator back in but then quits and only seems to start again when I take the freezer door off to crawl in there and check it. The evaporator coil has no frost on it at all. Any ideas as to what the problem could be? Any assistance would be greatly appreciated. Thanks, Shane

1 Answer

Shane, I am concerned about the lack of a frost pattern on the freezer evaporator coils. Even if the fan would not run, you still should have a frost pattern on the coils. You may have a sealed system problem. This could involve a failing compressor, freon leak, or even a valve that is not directing freon to the proper evaporator. If the compressor is running, you should have freon flowing throughout the system.

Read More...

1 Answer

Tanmay, you may have a defrost problem or air flow issue. You should be able to feel air flowing into the refrigerator through the air damper, if you don't, check the panel in the back of the freezer to see if there is a frost build-up which would indicate a defrost problem and not a sealed system issue.

Read More...

1 Answer

Eric,

You would want to check between the blue and brown for 120 vac. If there is proper power then this would be a compressor issue if the compressor is not starting.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google