Hello Hal. Programming Mode:
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Press and hold the Door Alarm Keypad DoorAlarm .
2. Press and hold Freezer Temperature Down Keypad .
3. Release the Door Alarm Keypad DoorAlarm and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.
6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate.
NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds.
7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to change the digit value with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit.
9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad until the Program CODE begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated.
The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes.

Read More...

1 Answer

Glenn, You will need to determine The correct board first. A MFI2266AEU 10 uses control board part number WPW10310240. A MFI2266AEU 11 uses control board part number WPW10310240. If you have the wrong "main control" in the unit, it will not accept the "personality code" and won't program. Please recheck your model number and order the correct part. Thanks and Good Luck

Read More...

1 Answer

Hello Peter. You will need to use the instructions sent with the control board WPW10310240 and program the control board for the unit. Then it should work properly. Hope this helps.

Read More...

1 Answer

Hi Peter. You need to have both controls at the mid point area. This should put the freezer at 0° and the fresh food between 37 and 47 degrees. If you can get the temperatures to stable, then ice production will occur as long as the front ice maker door seals as closed. The ice maker is part # WPW10190981. Are both the evaporator fan and the condenser fan motor running properly? Make sure the condenser coils are clean with cond. cleaning brush part # TJ103. Let us know if we can assist. you further. Thank you.

Read More...
Duncan for Model Number Maytag Refrig MF1266AES Cntrl Brd #AP4316852

Installed the new board and am having a similar problem. At step 4 confirming PE entry by pressing the Freezer Temp Down Keypad. The Current Program CODE value always comes up 0.000. I can enter the correct CODE with the Refrig Temp Keypad however when I hold the Freezer Temp Down Key I only get a beep and the lights will not flash. I have gone over and over this progamming mode several times with the exact same outcome. What could the problem be? Freon low? Some other electronic part burned out?

1 Answer

Hello Duncan. Make sure you are entering the correct code and doing it step by step for the instructions sent with the board WPW10310240. If not, the unit will not program properly. These can be hard to do and may require several attempts to get programed. Hope this helps.

Read More...

1 Answer

Duncan, If you replaced the main control board(on the back of the refrigerator) You have to make sure you order the correct replacement board WPW10310240 . And your time limits to program the new control are limited(2 to 3 seconds per step) and you have to follow the programming instructions precisely. If you miss a step or take too long, you need to unplug the power cord, wait a few seconds and start all over again. Thanks and Good Luck

Read More...

1 Answer

Hello Tony. You will need to program the control board. Here are the instructions from the manufacture. Hope this helps.
Service Specifications
Programming Mode:
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Press and hold the Door Alarm Keypad .
2. Press and hold Freezer Temperature Down Keypad .
3. Release the Door Alarm Keypad and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.
6. The control will display the current Program CODE. This value should be validated with the
Program CODE printed on the unit serial plate.
NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm
Keypad for 3 seconds.
7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to
change the digit value with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to
select the next digit.
9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad
until the Program CODE begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will
beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been
saved the Programming Mode is exited by pressing any key. If the new code is incorrect this
process should be repeated.
The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or
will exit if unattended for four minutes.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google