Questions & Answers

For Whirlpool Refrigerator Electronic Control Board (Part Number: OEM18057696)

1 Answer

Hello Joe. the fuse snaps into the bottom of the mold for the icemaker and is part of the harness.

Read More...

1 Answer

Hello Allen. Programming Mode:
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Press and hold the Door Alarm Keypad .
2. Press and hold Freezer Temperature Down Keypad within 3 seconds .
3. Release the Door Alarm Keypad and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.
6. The control will display the current Program CODE. This value should be validated with the
Program CODE printed on the unit serial plate.
NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm
Keypad for 3 seconds.
7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to
change the digit value with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to
select the next digit.
9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad
until the Program CODE begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will
beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been
saved the Programming Mode is exited by pressing any key. If the new code is incorrect this
process should be repeated.
The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or
will exit if unattended for four minutes.

Read More...

1 Answer

Hello Kim. Pull out the unit. On the back is a access panel. Remove it to access and replace the main control board in the unit. Remove the wires from the board and the board from the unit. Then install new board and wires. Now you will program the board in the unit.

Read More...

1 Answer

Hello Kas. First you will need to replace the overlay W10740218 on the unit. If the temp issue continues, you will need to check the temp sensors in the unit.

Read More...

1 Answer

Hello Vito,

You will want to make sure that the touch pad child lock is not on and if not then you would want to replace the HV board WPW10310240.

Read More...

1 Answer

Hello Cathy,

You will have to program the control board for it to work. To program, on the model/serial tag there is a code. You will push the door alarm keypad then push the freezer down keypad. Release door alarm keypad and approximately 3 seconds later PE or PE0000 will display. When this displays then you will release the freezer down keypad and then hit it one time. This will allow you to program the control. The Refrigerator up and down key will allow you to change digits to corresponding number of the code. To advance to the next digit you would push the freezer up key. Once the code has been entered you would push and hold the freezer down key. Display will flash letting you know that code has been stored. If the unit beeps at you when you enter code then the code is not registering and you will need to try again.

Read More...
Matt for Model Number MFI2569VEM

Over the summer, the freezer iced up badly several times, I thawed it out with a hair drier each time and after a week or two it stopped doing that and seemed fine. Recently, two new issues have cropped up: Apparently, the front display will now stop displaying actual temp, reverting to showing the set temp, after approximately 1 day of power - unplugging the fridge for a moment makes it show actual temp again, which eventually goes back to showing just set temp. Because of that issue, I missed the second problem initially - the freezer and fridge are no longer cooling nearly as well as they should, currently only capable of about 10 degrees below room temp. There is a little ice in the upper right corner of tubes/fins in the freezer compartment (can never remember if thats the evaporator or condensor) but nothing like when it was icing up over the summer, and melting it makes no difference. Except for the lack of sufficient cooling, the system seems to run fine - all fans/dampers/etc are running as they should, condensor is humming along with no unusual noises or excess heat. If it wasnt for the lack of coldness, I wouldnt even know something was wrong. Is this possibly just a control board issue, or is it more likely that the icing up caused a slight hole in the tubing that's been letting r134a slowly leak out and the system needs a recharge? There's a small stain where the ice was heaviest that might indicate a hole/leak, but I cant be positive it wasn't there from before that.

1 Answer

Hello Matt,

The way that you can tell if you are having a sealed system type issue is the temperature of unit. Evaporator coils in freezer compartment should have a full frost pattern. A full frost pattern tells you that there are no restrictions or leak in the system. There is a possibility that you do have a leak in the evaporator 12002730 that is causing issue. If there is a leak it would need to be repaired rather then recharged.

Read More...
Mark M. for Model Number GD5RHAXNQ00

Hi. My freezer is functioning fine except it was getting water at the bottom that was then freezing up. At that same time, the refrigerator stopped cooling (was close to room temperature). I could feel some cool air our the top vent in the fridge, but none from the middle one and the middle one was caked up with ice. I defrosted both sides. Now, there is no ice in the bottom of the freezer, but the fridge still does not get cold. Still some cool air out the top vent and none from the middle one. Also, the coils in the freezer have frost all over them. Please help???

1 Answer

Hello Mark,

Based on the information provided, the middle vent is your return air duct. You will not feel air blowing out of this vent. It sounds as if though you may have a defrost issue. If the coils are completely frosted up from top to bottom then you would need to check the defrost bi metal WPW10225581 and the heater WP2323198 for continuity. If it appears that the ice has been heated up and partially melted about half way up you may want to replace the bi metal as the unit may be terminating defrost too early. If the bi metal and heater are good and you have full frost top to bottom then you would want to replace the control board WPW10135090. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google