For Whirlpool Refrigerator Compressor Start Device Assembly (Part Number: OEM18049767)

1 Answer

Hello Laly,
If the model number is actually ED5GVEXVD07, you should remove the compressor start device WPW10189190 from the side of the compressor and shake it. If it rattles, replace it. If not, there is a good chance the thermostat WP2198202 has failed.

Read More...

1 Answer

Hello Loopherd,
You will need to look at the compressor on this unit to determine which part you will require. If the compressor says Panasonic on it, you will need to order part number 61003103. If it says TEC, you will need WP10097202. If replacing the start relay does not correct the issue, the compressor will be at fault.

Read More...

1 Answer

Hello Cortney. AppliancePartsPros.com is a company who assist DoItYourselvers repair their own appliances. We do not offer service repair at this time. We can suggest researching through your dealer or the yellow pages.

Read More...

1 Answer

Nancy, you forgot to include a model number, so we can't be sure what parts you may or may not need. If you haven't yet try this first set the refrigerator out in a cool dry area, remove the rear compressor compartment cover and the front kickplate grille. Let the refrigerator set for a week to 10 days, then try it again. You will most likely need a start device and capacitor as well as a condenser fan motor, at the least.

Read More...

1 Answer

Hello Cornelius,
This sounds like the relay 819098 has failed. I'm sorry but this part has been discontinued by the manufacturer and no satisfactory substitutions have been provided.

Read More...

1 Answer

Hello Don. No, if the start relay did not get the compressor going, then it sounds like the compressor is bad and will need to be replaced on the unit.

Read More...

1 Answer

Cory,

With the unit cycling every 3 minutes, it does sound like the start relay may have failed. You would want to replace the relay and if this does not correct it then the compressor would be the issue.

Read More...

1 Answer

Duane,

The first thing that you would want to try is a new relay as these are the most likely cause for the compressor to not come on. If the relay does not work then the compressor would have failed and need replaced.

Read More...

1 Answer

Hello Kamo,
This is most likely the electronic defrost control WPW10209636. This is more likely the defrost since the freezer is freezing up. If the compressor relay were not working, there would be no ice in the freezer.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google