The Dual Coil is an OEM part for GE dryers. This is often referred to as the “M” coil. If you need to replace both the main coil and dual coil, it is recommended to order the kit 279834, which includes both coils for a comprehensive replacement.
Causes of a faulty dual coil can include wear and tear over time, electrical component failure, or damage due to overheating or excessive usage. These factors can result in insufficient heat production, inconsistent drying, or no heat at all.
Symptoms of a bad dual coil may include:
This OEM GE part can also be used on Hotpoint, RCA, and Kenmore/Sears appliances.
I checked out a few youtube videos on trouble shooting a gas dryer that would not heat, like this one https://www.youtube.com/watch?v=Q8j6fQM3P34. Eliminated all the sensors as possible problems, leaving only the coils or more advanced problems. Took the chance it was one of the coils. I ordered both, replaced them both, put the dryer back together and fortunately that was the problem and it lit up and is running as good as new. Read more
The Door Latch is an OEM part for GE dryers. This part ensures the dryer door stays securely closed during operation, activating the safety switch to allow the dryer to operate. The latch mechanism engages with the door strike to lock the door, preventing it from opening while the dryer is running, which is essential for both safety and proper functioning of the appliance.
Causes for replacement can include normal wear and tear, accidental damage, or a misalignment that prevents the door from securely latching.
Symptoms of a bad Door Latch include:
This OEM GE part is also compatible with Hotpoint, RCA, and some Kenmore models.
My GE dryer from the late 80's/early 90's was squealing when it would start up, belt or bearing I was thinking. I found a manual online that covered my model and I watched a video on this site that showed me how to take it all apart, mine was a bit different but the principles were the same. I took it apart and added some quick-disconnects to 2 wires so next time I can take the front panel off easily. When I got to the bearing it looked worn but not bad so I cleaned it and put it back. ... Read more
The Main Coil is an OEM part for GE dryers. It is a crucial component of the gas valve assembly, responsible for opening the gas valve to allow gas flow to the burner, enabling the dryer to produce heat.
Causes of a bad main coil can include electrical faults such as short circuits or open circuits within the coil, wear and tear from prolonged use, or damage due to overheating. Over time, the coil's ability to control the gas flow can diminish, affecting the dryer's performance.
Symptoms of a bad main coil include:
This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models.
The Bearing Retainer is an OEM replacement part for GE electric dryers. It is an internal component that securely holds the drum bearing assembly in place to enable smooth rotation and provides structural bracing for the bearing during tumbling cycles.
Causes of a faulty retainer can include cracks from heat exposure over years of use. Impact damage from foreign objects inside the drum is also possible.
Symptoms of a bad bearing retainer include:
A few months back I changed out the "Bearing Slides" on the front side of the drum thinking that would stop the annoying squeaking every time we use the dryer. They were very worn and one was missing. But to my dismay it only lessened it by about 10%. After doing a bit more research I discovered the "Rear Shaft Bracket Assembly" also needed replacement. The tip was worn way down and clearly the source of the noise. It was actually a very simple repair except for the fact that the key to the... Read more
The LP Conversion Kit is an OEM part for GE dryers. It is designed to convert a natural gas dryer to liquid propane (LP) gas. This conversion kit ensures that the dryer operates efficiently and safely with LP gas, which requires different pressure settings and orifices than natural gas.
Causes of a bad LP conversion kit can include improper installation, damage to the kit components, or compatibility issues with the dryer model.
Symptoms of a bad LP conversion kit include:
This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models. For LP to natural gas conversion kit, order part number WE25X218.
I searched the internet and found the conversion kit to LP gas at Appliancepartspros.com. their price was the least expensive. The instructions were excellent in describing the removal of the nat. gas orifice and replacement with LP orifice. The part was delivered 3 days after ordered by Fed Ex., a speedy delivery! I finished installing my clothes dryer and it works fine. I have some experience with such equipment but recommend professional installation for reasons of safety! Thank you, R.P. Read more
The Flame Sensor is an OEM part for GE dryers. This part detects the presence of a flame in gas dryers, ensuring that the gas ignites properly for safe and efficient drying. Causes of a bad flame sensor can include regular wear and tear, carbon buildup from the gas flame, or electrical malfunctions. Symptoms of a bad flame sensor include:
GE Gas Dryer Model DBVH512GF1WW began to heat for only a short amount of time so drying clothes took WAY too long. Read online that the first thing to replace are the solenoids. Bought the two solenoids from AppliancePartsPros.com for about $50 total, and it seems to have fixed the problem. Had to watch a few videos to learn to disassemble the dryer, and the job took a couple of hours, but now that I know what I'm doing it could be done in less than 30 minutes. Also, the old solenoids tested... Read more
The Heat Diffuser is an OEM part for GE dryers. It is designed to evenly distribute heat throughout the dryer drum, ensuring efficient and consistent drying of clothes. The heat diffuser helps maintain proper airflow and temperature inside the dryer.
Over time, the heat diffuser can become worn out or damaged due to high heat exposure, lint buildup, or mechanical issues. Regular use and lack of maintenance can also contribute to its deterioration.
Symptoms of a bad Heat Diffuser include:
Removed 3 screws which required a torx bit. Used small headless nails to line up the holes and use as a guide for sliding on new diffuser. Put screws in one at a time and tightened down. rotating the drum helped with slight mis-alignement with the screw holes. Read more
The Thermistor is an OEM replacement part for GE dryers. This temperature-sensing device monitors air exhaust temperatures and communicates real-time readings to the control board. Precise thermistor functioning ensures the heating elements and drum engage safely and appropriately.
Symptoms of a faulty thermistor include:
Causes often relate to moisture exposure from normal operation degrading electronic performance over time. Physical stress or impact could potentially damage thin connecting wires.
This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore dryers.
Checked vent first to see if there was a blockage. Removed top, front and drum of dryer. Replaced all sensors including flame detection and gas valve coils. Re-assembled and tested. Dryer was now heating Read more
This metal mounting plate supports the dryer door strike/catch interface. It provides a solid anchor point so the door latches securely, helping the dryer start and run only when the door is properly closed.
We ordered a door switch, dryer latch and strike plate. We realized that we only needed to replace the door switch. We watched a few videos and then replaced the switch. We couldn’t find a video for our model but they did give us a pretty good idea about what we needed to do. The hardest part was getting the original door switch out, all of the videos we watched showed us that it would pop out with a little pressure from a flat head screw driver, from the front of the switch. We could not get... Read more
The Lint Filter Assembly is an OEM part for GE dryers. This part captures lint and debris from the air flowing through the dryer, preventing these particles from clogging the vent and ensuring efficient airflow.
Causes of a bad lint filter assembly can include physical damage such as cracks or breaks, wear and tear from regular use, or clogging from excessive lint buildup that can't be cleaned effectively.
Symptoms of a bad lint filter assembly include:
I ordered a new filter and replaced the torn one. Read more
The Trap Duct Assembly is an OEM part for GE dryers. This part directs the airflow from the dryer drum to the exhaust vent. This assembly ensures efficient drying by guiding hot air out of the dryer while collecting lint and debris in the trap, preventing it from clogging the venting system.
Causes of a bad trap duct assembly can include lint buildup over time, physical damage due to heavy usage, or obstruction from foreign objects.
Symptoms of a bad Trap Duct Assembly include:
Our GE front loader dryer is approximately 10 years old. It started making a loud noise. Before we sank another $600 for a new dryer, I decided to go online to search Youtube videos to try to find out if anyone else had the same problem. I found that a lot of dryers had drum support bearings that wore out and needed to be replaced and a lot of dryers were also having clothes caught up in them. I then found an Appliance Parts Pro video on how to fix this problem and found out what parts... Read more
This replacement part is a high-limit thermostat, and it is intended for use in different types of appliances. This is a genuine replacement part made by General Electric. This high-limit thermostat is typically found in dryers and controls the heat inside the drying tub. This is especially important as different dryer settings require different amounts of heat. If the high limit thermostat works properly, the temperature inside the tub should reach the correct amount during each drying cycle with no issues. A new high-limit thermostat might be needed if the user notices that the dryer is unable to reach the appropriate level of heat for a certain drying cycle. This is also true if the dryer is becoming too hot when the heat is supposed to be set to low. Make sure the dryer is cooled down prior to replacing this part as the areas in the back of the dryer can become very hot during use. Be sure to reference the specific user manual for more instructions on how to replace the thermostat. This thermostat is sold individually and is a genuine OEM part. The thermostat is sourced directly from the manufacturer.
Replaced thermal stats Read more
This cleaning felt mounts on the dryer's front shroud. It lightly contacts the rotating drum to wipe away lint and residue, helping keep the drum edge clean and supporting consistent airflow to the lint filter.
Selected and ordered parts from online drawings. Watched videos showing how to make repair. Replaced worn parts with new ones. Suggested improvement: Videos didn't show my model (I know there are many models, showing all is probably not possible). In case of Felt the video showed a Maytag dryer when my model was GE. In my case Felt had torn and dislodge from slot so I didn't know exactly how it should be installed. A simple picture of the installed Item would help. Also the parts list should... Read more
This outlet backup thermostat for dryers mounts on the exhaust duct and provides secondary over-temperature protection. It shuts the heater off if exhaust air gets too hot, helping maintain safe, consistent drying.
This replacement blower wheel for a dryer mounts to the drive motor and pulls air through the drum, lint filter, and exhaust, restoring proper airflow so loads dry efficiently and the appliance runs as intended. What it does:
Mounted inside the dryer drum, this replacement baffle lifts and separates laundry as the drum turns to improve airflow and even drying. Replacing a cracked or missing baffle restores quiet, effective tumbling and helps prevent fabric damage. What it does:
I ordered two new baffles and 7 screws. I also ordered 6 large washers. We were running with one baffle held by only 2 of 3 screws. It appears that a repairman in the past had removed the large washers and over time, the screw heads reamed out the hole, causing the baffles to detach and break. In about 15 minutes, I was able to tighten up the existing baffle and add the two new ones. I also added the 6 big washers to help strengthen this to prevent future issues. I no longer have to listen to... Read more