1 Answer Edgewater Appliance, We have sent an instruction sheet for this dual infinite switch. The diagram has a dotted line around it and the letter or number on the outside is the new switch marking and the inside of the dotted line is the markings of the old switch. Follow instructions for the jumper wire and in the case, you are installing this on the cve3400 model the two red wires connected to the L2 spot on the right front switch needs to be separated and the one that is not a jumper from switch to switch will need to be connected to the number 2 on the new dual switch. Read More...
Zufan May 24, 2019 for Model Number JED8430ADB i bought dual infinite switch to replace my Jennair right front dual control switch but terminal does not macth to replace with new dual switch part number 12002125.please assist me. old switch terminal 1 2.3 4 5 6 N new one s1 s1 p1 4 4a p2 thank you
1 Answer Zufan, black jumper goes from P1 to S1, this brings voltage to the surface indicator circuit. 2 goes to P1, N goes to P2, 3 goes to 4, 4 goes to 4a, 5 goes to S2. P1 and P2 are your incoming voltage to the switch, 4 and 4a take voltage to your element. S2 is the voltage going to the surface indicator light. Read More...
Dr. D March 29, 2019 for Model Number Jen Air CVE3400B down draft Hello, will this replacement part 12002125 Dual Surface Burner Switch Kit work with Jen Air CVE3400B down draft cook top? Does it come with a install instructions with the switch ? Thanks Dr. D
1 Answer Dr. D, the dual burner infinite switch kit [12002125] will work with your model and it should come with an instruction manual in this kit. Read More...
Jeff January 27, 2019 for Model Number infinite switch I installed an infinite switch and the burner stays on high. Did I switch wires during installation to cause this?
1 Answer Jeff, it is very possible that the wires are switched around. If the wires are not correctly placed, it can cause a constant high heat when engaged. Read More...
Robert December 05, 2018 for Model Number JES9800AAB Second from left switch had a wire going from switch to indicator light on stove. Repair part 12002125 does not have a place to connect the wire. How do you get the indicator light to work. Could you check my work. Black=P1 Blue=4 Tan=4a Orange=S2 Red from burner=2 Red jumping across the other switches P2 Jumper P1-S1 (stove might be 2003)
1 Answer Robert, According to the wiring diagram here is how the unit should be wired. Black to P1, Tan to 4, orange to 4a, inidcator light wire to S2, Jumper wire from black to P1, Red double wire to P2 and purple to terminal number 2. Read More...
Gerald B September 22, 2018 for Model Number Jenn-Air CCE3401B Ordered a 12002125 switch to replace faulty Left Rear burner switch. The new 12002125 switch and the old switch have different terminals. Here is how I connected: * Attached the Black wire from the old switch (terminal 2) to the new switch terminal P1. Also attached jumper wire between P1 and S1. * Attached Light Red wire from old switch terminal 5 to S2 on the new switch. * Attached Shiny Blue wire from old switch terminal 4 to 4a on the new switch. * Attached Shiny Black wire from old switch terminal 3 to terminal 4 on the new switch. * On old switch two Red wires were crimped together and attached to terminal N. Separated the Red wires from each other and attached the one from power cable to P2 on the new switch. Attached the other newly split Red wire from the Left Front burner switch to terminal 2 on the new switch. Problem I am having is circuit breaker trips as soon as I try to turn on the Left Rear burner using the new switch. What do I have connected wrong?
1 Answer Gerald, It sounds like you have everything attached properly and would suggest checking for damaged or pinched wiring. Also check the element to make sure that there are no damaged wires. Read More...
Mike September 19, 2018 for Model Number CCE3401 I am trying to replace a dual burner infinite switch [part #12002125] on a 20+ year old Jenn-Air Radiant Cooktop. Old Switch(terminal=wire color):2=Black, 3=Blue, 4=Purple, 5=Orange, N=Dual Red I have wired the new switch in 3 ways. In all 3 configurations I put the jumper between P1 and S1 First Way: causes burner to be constant on high P1=Black, 4=Blue, 4a=Purple, S2=Orange, P2=Dual Red Second Way: causes burner to be constant on high Split dual red: one from burner and one from LF L2 P1=Black, 4=Blue, 4a=Purple, S2=Orange, P2=Red from LF L2, 2=Red from burner Third Way: blows the circuit breaker No dual red wire split P1=Black, 4=Blue, 4a=Purple, S2=Orange, P2=Dual Red Please Help!
1 Answer Mike, your second way is correct. Check the contacts on the limiter switch that is on the element. You will need to allow it to get hot before you can get an accurate reading. When it gets hot, pull one of the wires off of the 2a or 1a connections and check for continuity. This switch should open up when it gets hot, this is how it regulates the temperature of the element. Read More...
Val May 26, 2018 for Model Number JES9800AAW What is the correct replacement part for the infinite switch (back left large burner)? Thank you
1 Answer Hello Val, You will need to order 12002125 for the infinite switch for the left rear dual element on the model provided. Read More...
Ruth May 26, 2018 for Model Number JES9800AAB Inf Switch Kit (Dual) AP4008679. Is this the correct part for the element control with the dual control, the second knob from the left? Also, do you think that replacing the control panel will restore the buttons that are currently not working? Thanks
1 Answer Hello Ruth, You will need to order 12002125 for the dual infinite switch for the dual surface element. The control panel WP74005747 contains the membrane switch which are the buttons you referred to as being inoperative. Read More...
Phil Trotta February 05, 2018 for Model Number JED8430ADB-12646392ZD 12002125 INF SWITCH. DESPITE MUCH EFFORT BY STAFF,i HAVE YET TO PLACE ALL EXISTING WIRES ON THIS SWITCH. THE ISSUE IS ORANGE INDICATOR WIRE. WHICH IS IN SOME SET UPS PLACED ON 4A TAB. WHICH IS ALSO FOR YELLOW ELEMENT WIRE..I WOULD REALLY LIKE TO HAVE INDICATOR LAMP OPERATIONAL. THIS SWITCH SHOULD ADDRESS THIS. WOULD INDICATOR GO TO S1? OF CAN ONE PIGGYBACK YELLOW AND ORANGE ? DO NOT UNDERSTAND JUMPER FROM P1 TO S1. AS IT STANDS ALL TABS OCCUPIED BUT ALWAYS WITH ONE WIRE LEFT. EITHER ORANGE INDICATOR OR YELLOW ELEMENT. HELP APPRECIATED.
1 Answer Phil, The On indicator light /orange wire should attach to the S2 terminal on the 12002125 infinite switch. The only Jumper wire on the switch comes with the kit and is attached to the P! terminal and the S1 terminal. Here's some help: black common wire(to all switches) attaches to the other P1 terminal, Tan wire attaches to terminal $, Yellow wire attaches to terminal 4A, S1 term orange, S2 terminal black jumper wire, Red common to all burners will attach to P2 terminal, Red wire to the element will attach to Terminal 2. Read More...