The Spark Module is an OEM replacement part for Whirlpool ranges. It is an electrical component that generates the spark needed to ignite the gas burners. By sparking consistently and reliably, the module allows the cooktop burners to ignite with each use. 

Causes of a bad spark module can include normal wear and tear over time, exposure to moisture or residue, or issues with the electronic components that produce the spark.

Symptoms of a bad spark module include:

  • Burners that will not ignite or light consistently  
  • Burners that ignite but then immediately go out
  • Only some of the burners lighting while others do not
  • A clicking sound coming from the ignitors but no visible spark

Note: For harness from spark module to igniters use part number 9756892.

This OEM Whirlpool replacement spark module is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper, and Kenmore models. 

More
$226.54

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Spark Module (Part Number: OEM18059193)

1 Answer

Hello Kenny. If the broil is sparking, but not the bake, and the igniter is good, you will need to replace the spark module WPW10331686 on the unit. Hope this helps.

Read More...
Ronald S. for Model Number Kitchen Aid KGSA906PSS00

I had a problem with my KGSA906PSS00 not warming up to more than 200 and the bake ignitor not lighting. I replaced the spark module as both DC outputs read low on the old module and now the broil will get up to 350 and when it's in the bake mode you can smell gas. I checked the gas valve resistances and the bake side reads good, but the broil side reads open. When I checked the DC outputs from the spark module it read good in broil mode but nothing in bake mode. Looking at the wiring I don't see any chafing that would suggest a short anywhere. Any help would be appreciated as I'm confused on this one.

1 Answer

Hello Ronald,

I would recommend to replace the burner 8191123 and the safety valve WP9763716. This is not a guess, but a recommendation as a gas unit is more sensitive, (and dangerous), than an electric unit. Anytime you're dealing with an explosive gas it's a good idea to replace anything that could potentially become a hazard. I base this diagnosis on the fact that you could smell gas while the unit was operating. It's normal to smell gas immediately after start up but never during operation.

Read More...

1 Answer

Hello Cathy! Make sure that the area where the comes out of the burner is free of any debris. If that is ok, you will need to try to replace the ignitor WP8523793. Thanks!

Read More...

1 Answer

Buck, You're almost done, Now you need to run the DCV checks from the DSI module. On J1 pin1 red wire, you should read 8 to 18 VDC in the bake mode, and J1 pin3 blue wire, should have the same VDC, in the broil mode and J1 pin 2 orange is the common lead for both tests. At the gas valve assembly WPW10293048 check the resistance from the center terminal to each outside terminal you should have a resistance of 215 ohms on each test. Also check for the same VDC from the module. If all checks OK, replace the gas valve assembly. Thanks and Good Luck

Read More...

1 Answer

Hello Connie. Based on the information you provided, it sounds like the electronic control WP9762793 is bad and will need to be replaced. Hope this helps.

Read More...

1 Answer

Gerry, The DSI spaerk module, is a very good place to start. If the "re ignition" circuit in the board has failed, the spark ignition to the oven will not work. You also need to check for damaged wires or loose connections at the gas valve wiring and igniter as well. Good Luck and Thanks

Read More...

1 Answer

Hello Jim. The range does not need a GFI outlet, and the outlet could be the problem. However, if it has worked properly there in the past and is just now starting, then it sounds like the spark module WPW10331686 is bad and will need to be replaced or the outlet is weak and needs to be replaced. Hope this helps.

Read More...

1 Answer

Hello Augusto. Based on the information you provided, it sounds like the spark module WPW10331686 is bad and will need to be replaced. Hope this helps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278