Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Refrigerator Compressor Start Device Assembly by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM18049767
Manufacturer Part Number: WPW10189190

Refrigerator not cooling or compressor won't start? This start device assembly includes relay and overload. DIY-friendly 15-minute repair for most models.

More
$81.95

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Refrigerator Compressor Start Device Assembly (Part Number: OEM18049767)

Brenda for Model Number NNS228GA

I bought the relay/overload start device combo and I have a question...There are only 2 visible places on this new start device to attach the wires that are coming from my fridge. Which ones do I use? From the fridge, I have 1 black (or dk blue)wire, and then another clip/connector with a combo of a white and 2 black (or dk blue)wires going to the old relay. The old relay plugged onto 2(bottom) of the 3 posts of the compressor. The top post of the compressor has a black wire connected that goes to the overload. There is also an orange wire going to a connector on the overload and a dk blue wire going to a separate connector on the overload. which ones go where?

1 Answer

Hello Brenda,

You will have to trace wires back to the condenser fan motor. The hot wire coming off the condenser fan motor, either blue or orange will go to the L1 on the new relay. The white wire from the condenser fan will go to the N on the new relay. The other wires will be eliminated from the circuit at this point.

Read More...

1 Answer

Hello phucthefridge. You need to make sure the power is disconnected. You will pull the relay off the unit first. Then the overload pulls off the compressor. If there is a cover on there, you will need to remove the cover to access and remove the parts. Both parts in the start kit WPW10189190 pull off the compressor.

Read More...

1 Answer

Hi Mike. Access your wiring diagram in the controls or the toe kick area. Blue / black combo. to the overload. Gray to the "S" terminal of the compressor from the capacitor. White from the capacitor and the other blk./ cond. fan motor goes to the "R " side of the compressor. Thank you.

Read More...
Dave for Model Number SX25SW

Hello! I have the blue and black connected to the overload L as per the original connections and the circuit diagram. I have the other black connected to N and the capacitor is plugged into the bottom two slotted connectors. I forgot to mention in the email that the white and grey are not conencted. The white originally went to the other black that is connected to N and the grey went straight to the capacitor. I have checked the white and it appears that it is connect not to the capacitor but somewhere else. That is why I am asking if it should be connect to the black as it was originally. Be Well, Dave

1 Answer

Hello Dave. Yes, the only wire you will not need is the grey wire. You will need to use the white wire with the black wire or it will not run. You have everything else wired correctly. Hope this helps.

Read More...
Dave for Model Number SX25SW

Hello! I have followed the advice of the tech and have the start device wired and with a new capacitor as per the instructions I received. This device is even less functional than the old one as now the condenser fan does not even start. Before the condenser cooling fan would run but the compressor would not start. Now nothing runs but the lights. Any suggestions? With the old parts back in place the condenser cooling fan runs but there is a loud click. It seems like the start device is the problem.

Dave for Model Number sw25sx

I do not see how to connect this new style part in place of the old one. The new part came with no diagram and half of the terminals are not labled and there are fewer terminals. This is the first email I sent trying to get some help: Hello! The following answer is the one that makes the most sense as I do not have any orange wires: "Hello Dave. According to the information provided by the manufacturer, the Blue will connect to L, white connects to N. Regarding the two black one's, you will have to adapt the female ends to male and connect it to the center of the start device. Thanks!" However, I also have a grey wire. Where does this wire connect? Also one of the black wires is in common with the white wire. I seem to have more wires (5) than I have possible connections (4.) First email ends. I then sent a follow up email: Hello! In looking at the wires and the circuit diagram on the back it appears that the grey and white wires go to the starting condenser at one end and the other end of the grey wire goes to the small brown relay(?) at pin #three and the combined white and black wires connect to pin #two and pin #one is unused . The single remaining AC wire connects with the blue wire on the overload and in looking at the part they appear to be in common. I am still unsure how these wires connect to this new replacement unit. I hope this extra information helps. Perhaps if you have the circuit/wiring diagram for this replacement part I could make sense of the connnections. Second email ends. I am anxious to fix this fridge (I have been without it for a week) but how can I without the diagram? Can you please help me make sense of this? Regards, Dave

1 Answer

Hi Dave . Access your wiring diagram in the controls or the toe kick area.Blue / black combo. to the overload. Gray to the "S" terminal of the compressor from the capacitor. White from the capacitor and the other blk./ cond. fan motor goes to the "R " side of the compressor. Thank you.

Read More...

1 Answer

Hi David. Is the model # SRD27S4E..? If so then the blue to the overload. Black to the cond. fan motor. one side and black to the ptc. common @ the compressor(r) connection also with the black and white to the capacitor one side. The other side from the capacitor (gry) to the p.t.c. common with the (s) compressor connection. The wiring diagram is on the back of the unit, or folded in the controls @ fresh food section or in the front kick panel folded up. Thank you.

Read More...
Rajesh for Model Number Maytag MCD2257HEQ

My Maytag MCD2257HEQ fridge stopped cooling after hurricane Irene. We had a power outage. I found that there was no AC input to the compressor & also the condenser fan was off. I hot wired the compressor and it runs but gets very hot--how hot is it supposed to run? Further trying to diagnose the problem, I found that the the Control Board Trace from the Compresser power relay was blown on the board. I bridged the trace with a wire and I got the Condenser fan to run. I am hesitant to put the compressor back on, not knowing why the trace burned. I would have though that the overload relay was supposed to prevent this from happening. I have extra spare capacitors--can I just order the overload relay? Thanks, Rajesh

1 Answer

Hi Robert. The blue is connected to the overload. The gray wire to the capacitor. The orange wire's connect to the # 1 connection on the relay. The capacitor wires will both go to the relay, one wire to the # 1 terminal/relay, the other onto # 3 of the terminal/relay. Thank you.

Read More...

1 Answer

Hello Richard. You will need to determine which wire is a line wire and which wire is the neutral. The line wire goes to the L and the neutral wire goes to the N. Hope this helps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278