Customer Questions and Answers for Refrigerator Dispenser Switch by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM17065971
Manufacturer Part Number: WR23X10783

Water or ice dispenser not working? This dispenser switch activates when you press the lever. Easy DIY repair—takes about 30 minutes with basic tools.

More
$49.95
Compare At:
$59.44
You Save:
$9.49

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Ge Refrigerator Dispenser Switch (Part Number: OEM17065971)

1 Answer

Hello Shon, This is most likely a power supply issue on the main board WR55X10942C. While there is the chance that the dispense board WR55X10859 had incurred damage, it is more likely to be an issue with the main board.

Read More...

1 Answer

Rhonda, The most likely cause for the dispenser to not stop dispensing water would either be that the switch is sticking or the water valve on the unit is not closing. You would want to check the switch to make sure that it is good and if it checks ok then the water valve would most likely be the issue.

Read More...

1 Answer

Hello Bill, If the switch WR23X10783 tests good and the connections and wiring harness are in good shape at the door hinge, The board WR55X10195 is the most likely suspect. Be sure the freezer compartment is not below 0°F as this can cause condensation on the auger motor and cause stoppage. Also be sure to shine a light from the outside while looking down into the ice chute. If light can be seen, air can leak through and cause condensation issues. If there is any rust on the solenoid WR62X10055, it should be replaced.

Read More...

1 Answer

Hello Jzack. Check all the wiring connections and the hose connection at the bottom of the door. Also, make sure the water is turned on.

Read More...

1 Answer

Juan, The most likely cause for the unit shutting down would be caused by a possible short in the wiring at the bottom of the door or a bad control board.

Read More...

1 Answer

Dan F., You will want to check the wire harness at the bottom of the door to make sure that the harness is not damage or have broken wires. If the wiring checks ok then the main control board would be the issue with the main control board.

Read More...

1 Answer

Hello Chris, If the water pressure to the valve is low or the new valve is defective, there will be residual runtime, (3 seconds after release is the symptom), just as there is when air gets in the system. There is also the possibility of a loose water line or a pin hole in a water line allowing air into the system. It is important to throw out about 2 gallons to ensure all of the system is properly purged.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store