For Lg Sensor Assembly (Part Number: OEM17020158)

1 Answer

Hello Carlos. The drying poorly issue and the vent assembly is where the air comes out of the dryer assembly and it removes the warm moist air in the unit.

Read More...

1 Answer

Hello Carlos. Yes, the sensor 6501FA2462E can cause this issue. Most of the time the issue is the vent assembly not properly working and it causes the issue you are having.

Read More...

1 Answer

Hello Travis.

The sensor you were lookin at is the ball sensor used to sense an out-of-balance load. The hall effect sensor is part number 6501KW2002B.

Read More...

1 Answer

Hi Jeff. The U.E. code can be from anything that will allow the unit to be unbalanced. • The load is too small.• The appliance is tilted.• Laundry is gathered to one side.• Non distributable things are put into the drum. Make sure that the unit is level front to back and side to side. Make sure the level legs are locked with the nut tightened back towards the base. Make sure the legs can grip a clean floor. If the legs are damaged they are part # AFC72909501. Remove the top. look to see if the top center tub springs are located in the top frame mounts and lightly greased. They need to be replaced in pairs. They are part # 4970FR2084N. Open the back and see if the tub shocks are loose or if there is any grease or oil leaking out. They are part # 383EER3001E. If the holding pins are broken replace them with part # 4774FR3118B. Open the door and with no clothes, spin the tub and see if there is more than 3/8" run-out (up and down movement) of the tub. Make sure that it is not wearing into the front of the boot assy. The tub is part # 3045ER1006E. Check the back pulley bolt. Is it tight ? It is part # 4040FR4051C. Are all the shipping bolts in the back removed ? Thank You.

Read More...

1 Answer

Hello Mike. Check and make sure none of the rotor magnets are cracked or broke. If they are good, then you will need to replace the stator assembly 4417FA1994G. It comes with the RPS sensor. Hope this helps.

Read More...

1 Answer

ball sensor assy. cannot be ohmed for continuity. It emits the a frequency of light to send to the main control board if the ball is move out of the "resting" hole during the beginning of a bad rotation cycle. Then the main control board will stop the rotation and start a slow rotate and counter rotation to re balance the load before it ramps up again. The sensor mounts on the original mount with a screw that was with the original one. This sensor is part # 6501FA2462E. Thank You.

Read More...

1 Answer

Hi T.J. U.E. = IMBALANCE
ERROR. The load is too small.
• The appliance is tilted. Make sure the unit is leveled from front to back and side to side with the level legs "stud nuts" locked tight up against the base.
• Laundry is gathered to one side.
• Non distributable things are put into the drum. Redistribute the clothes evenly. Replace the part # 6501FA2462E. Thank You.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store
​