Customer Questions and Answers for Ice Maker Cutter Grid by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM8709498
Manufacturer Part Number: 2174861

This grid assembly cuts ice into uniform cubes as it rotates within the ice maker mechanism. Located inside the ice maker module, replace it when ice cubes are irregularly shaped, too large, or when the ice maker fails to produce ice properly.

More

Questions & Answers

For Whirlpool Ice Maker Cutter Grid (Part Number: OEM8709498)

1 Answer

Hello Gary, thank you for contacting AppliancePartsPros.com
No, you would need to access the wires going to the cutting grid, voltage cannot be tested on the cutting wires of the grid.

Read More...

1 Answer

Ira, it would be recommended that the cutter grid WP2313637 is tested for resistance and it should measure 20 Ohms. If it does not measure the proper resistance, it will not cut the ice properly. If it tests good, then the failure would be in the transformer WP2310139 if there is not a corroded wire.

Read More...

1 Answer

Jeff, the grid cutter W10919199 should measure a resistance of 5O and it receives a voltage of 9.4VAC from the transformer WPW10485951. The cutter grid is only going to get warm enough to cut through the ice so that the cubes drop through before the next ice slab is ready to harvest.

Read More...

1 Answer

Hello Jeff,
I'm sorry but this part W10919199 has been discontinued by the manufacturer and no satisfactory substitutions have been provided. Thank you for your patience and understanding in this matter.

Read More...

1 Answer

Terry,

Unfortunately we do not have a timing chart on this unit but the unit will fill first, then pump water across the evaporator, then it will drop the ice to the heater and cut it.

Read More...

1 Answer

Joel, Sorry, but No, you shouldn't " use it in a regular electric outlet directly" The grid cutter wiring is designed to operate on eight(8) volts AC, and has 4 to 5 ohms resistance, so maximum voltage would be an additional 10 %, making the voltage range 7 to 9 VAC. Applying 120 VAC to the grid would cause premature failure of the part. Sorry.

Read More...

1 Answer

Hello Joe. You will need to check the transformer and see if it is bad and will need to be replaced on the unit.

Read More...

1 Answer

Hello Andres. If the voltage is there, you will need to order and replace the cutter on the unit.

Read More...

1 Answer

Clay,

The model number that is listed is not coming up as being valid. With most of the icemachines the voltage to the cutter grid would be between 12 and 24 vdc. 10.5 would be low and would most likely be caused by a faulty transformer.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google