Need Help?
Call or text
Some parts shown may not be for your model. To see parts for your model only, select it from "Matching Model Numbers" list on the left.
The Dispenser Door Recess Crank is an OEM part for GE refrigerators. This crank is a crucial component of the refrigerator's ice and water dispenser system, helping to operate the dispenser door by opening and closing it when activated. It ensures that ice or water is dispensed efficiently and prevents unwanted air from entering the freezer compartment.
You should replace the dispenser door recess crank if it becomes faulty or damaged. Causes of a bad crank can include wear and tear from frequent use, accidental damage, or mechanical failure. A malfunctioning crank can lead to issues with the dispenser door's operation.
Symptoms of a bad dispenser door recess crank include:
This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models.
My refrigerator is 13 yrs old and began to build up frost in the ice cube shoot and the water tube began to freeze up over night. The flapper door was not closing completely. I simply removed the control panel by pulling up and out on the bottom edge, the edge is only about 1/8 inch thick, so don't reach in to far. You should be able to feel a small division line between the control panel and the refrigerator. No screw driver was needed to expose the 4 mounting screws of the inner dispenser... Read more
The Water Tank Plastic Tube is an OEM part for GE refrigerators. It functions as a conduit, transporting water from the water tank to the dispenser and ice maker, ensuring a steady flow of water for these features.
You should replace this plastic tube if it becomes damaged or worn out. Causes of a bad water tank plastic tube can include wear and tear over time, blockages from mineral deposits, or physical damage from mishandling or kinks.
Symptoms of a bad water tank plastic tube include:
We noticed a puddle of water in front of the fridge a couple of months ago-dried the floor up both times and thought someone had dropped ice-or spilled water. A couple of weeks ago there was water dripping through the dropped tile ceiling in the basement. I shut off the water for the water supply to the fridge at the copper pipe in the basement and removed some of the tiles which felt a little damp. It still dripped all day. When my spouse came home he pulled down more of the tiles. It was as... Read more
The Compression Ring is an OEM part for GE refrigerators. It is designed to secure and seal connections within the refrigerator’s water and ice dispensing system, ensuring a leak-free operation. This small yet vital component helps maintain the integrity of the connections, preventing water leaks and ensuring the proper flow of water through the dispenser and ice maker.
Over time, the compression ring can wear out or become damaged due to regular use and the natural aging of materials. If the compression ring is compromised, it can lead to water leaks or poor water flow, which can affect the overall performance of the refrigerator’s water and ice dispensing functions.
Symptoms of a bad compression ring include:
Replacement of the evaporator fan motor, fan blade, and grommets. The amount of disassembly to reach the part took most of the effort Read more
The Dispenser Housing Shield is an OEM part for GE refrigerators. This component plays a crucial role in protecting the internal mechanisms of the water and ice dispenser from damage and contamination. It ensures that the dispenser operates efficiently and maintains hygiene standards by shielding the delicate internal parts from debris and moisture.
Causes of a bad dispenser housing shield can include wear and tear over time, physical damage from excessive force or mishandling, or exposure to moisture that leads to material degradation. Regular inspection and maintenance can help in identifying issues before they affect the dispenser's functionality.
Symptoms of a bad dispenser housing shield include:
BEWARE THE HAIRDRYER In an effort to unfreeze the indoor water supply line with a hairdryer the extreme heat deformed not only the activator paddle but the housing that surrounds it. In the time it took to order and install replacement parts the frozen blockage had thawed. Back in business for now and if the problem reoccurs I will be looking for a different path to resolve the issue. Read more
The Dispenser Light is an OEM part for GE refrigerators. It illuminates the water and ice dispenser area, providing visibility when accessing these features in low-light conditions. This light enhances user convenience and helps to ensure accurate and spill-free operation.
Causes of a bad dispenser light can include burnout from regular use, electrical issues, or damage from moisture or impacts. A faulty light can compromise visibility and the overall functionality of the dispenser area.
Symptoms of a bad dispenser light include:
We bought a new house that has a 15 year old GE Monogram built in fridge. The home warranty people sent two guys out saying it was nearly impossible to repair the fridge and they both suggested buying a completely new freezer door for the fridge and of course the warranty company said it was preexisting and we weren't covered. Shocker. I have lighting in the freezer but not the fridge. I purchased a door switch and replaced the old one but that didn't do the trick. So i purchased a 2 amp fuse... Read more
The Condenser Fan Blade is an OEM part for GE refrigerators. It is responsible for moving air across the condenser coils to help dissipate heat, allowing the refrigerator to maintain the proper cooling temperature. This fan blade ensures efficient operation of the cooling system by facilitating proper airflow.
You should replace this condenser fan blade if it becomes damaged, warped, or fails to move air effectively. Common causes of a bad fan blade include physical damage from debris, wear and tear over time, or warping due to prolonged exposure to heat.
Symptoms of a bad condenser fan blade include:
Condenser fan stopped on my big 2003 Monogram 4 foot wide ZIS480D Refrigerator. It is top mounted. The fridge had to be rolled out. 20 screws removed and the top sheet metal to get at the condenser. That was the only way to get at it. Works like new now. Read more
The Fastener Door Handle is an OEM component for GE refrigerators. This door handle provides a comfortable grip for accessing refrigerator shelves and bins. It attaches securely to the refrigerator door through durable metal fasteners.
Causes for a bad door handle could be cracks, damage, or stripped fastener holes resulting in a loose or detached handle. Regularly gripping and lifting may also cause normal wear over time.
Symptoms of a failing door handle include:
This OEM GE handle is also compatible with Hotpoint, RCA, and select Kenmore refrigerator models.
I 100 percent recommend Appliance Pros. This was by far the best experience I've ever had making a purchase on line or via the the phone. Read more
The Lid Bumper is an OEM part for GE refrigerators. It is designed to provide cushioning and protection for the refrigerator lid, preventing damage and ensuring smooth, quiet closing.
Causes of a bad Lid Bumper can include deterioration over time due to frequent use, exposure to temperature variations, or damage from accidental impacts. A worn or damaged bumper may no longer provide adequate cushioning, leading to potential damage to the lid or the refrigerator itself.
Symptoms of a bad Lid Bumper include:
Changed fan motor, rubber grommets, and dust cover. It sounded like the vibrating sound was being caused by the motor. But, come to find out I had a chipped blade on one of the fan blades. So make sure and check the fan blade first. Thanks Appliance Parts Pros everything for just as it should. Read more
The Dispenser Drip Tray is an OEM part for GE refrigerators. It serves as a catchment area for any drips or spills that may occur during the dispensing process. It helps prevent water or ice from dripping onto the floor or making a mess on the front of the refrigerator. For white order WR17X11654.
Causes of a faulty or damaged dispenser drip tray can include regular use, accumulation of debris, or cracks. These factors can result in issues such as water or ice leaking onto the floor, an unsightly appearance, or difficulties in cleaning and maintenance.
Symptoms of a bad dispenser drip tray may include:
This OEM GE part can also be used on Hotpoint, RCA, and Kenmore/Sears appliances.
Watched your videos and easily replaced the solenoid, spring, flapper etc. The only reason it took me as long as it did is I have a GE monogram side-by-side in cabinet refrigerator. It is stainless steel and required me to take off all of the stainless steel skin on the freezer side door. While this was not that difficult it was time-consuming. Read more
The Solenoid Valve Kit is an OEM part for GE refrigerators. This kit includes the solenoid valve, which is responsible for regulating the flow of refrigerant in the cooling system.
Causes of a bad solenoid valve kit include electrical malfunctions, physical damage, refrigerant leaks, or general wear and tear over time.
Symptoms of a faulty solenoid valve kit:
This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore refrigerator models.
This was a two and half year issue as different things failed at different times. I would get one part, then another would fail. Ultimately, I got to a point where what failed, I hadn't been ordered the part yet. The seal on the freezer door took three bathing's before it plumped up and un-creased. The directions on the box it is shipped in said to heat the seal up in hot water then cool it down with tap water. I didn't need to do that. It took a lot of massaging of the seal, but... Read more
The GE Door Light Switch is an OEM Replacement Part that serves as the Freezer Door Fan and Light Switch. The switch is made from metal, wiring, and plastic. It plays an essential role in energy conservation by turning off the light when the refrigerator or freezer door is closed
Over time, the door light switch can wear out or fail due to frequent use, exposure to moisture, or electrical issues. When this happens, the interior light may not function correctly, which can hinder visibility inside the refrigerator.
Symptoms of a bad door light switch may include:
This switch is compatible with select GE and Hotpoint models.
Pop out the old switches with a putty knife pressing down on the tab, grabbed with pliers to pull out, disconnect the wires and connect new switches, pressing back in place. Read more
The Dispenser Arm Spring is an OEM part for GE refrigerators. This spring is a crucial component that helps control the movement of the dispenser arm, ensuring it returns to its original position after use. It plays a key role in the functionality of the ice and water dispenser, allowing for smooth operation and consistent performance. Please note the springs are sold individually.
Causes of a bad Dispenser Arm Spring can include wear and tear from frequent use, corrosion due to moisture exposure, or accidental damage from excessive force. A malfunctioning spring can lead to operational issues with the dispenser.
Symptoms of a bad Dispenser Arm Spring include:
I order both the paddle and spring and watched a video on how to remove the operating panel to replace them Read more
The Compressor Inverter Board is an OEM part for GE refrigerators. It controls the operation of the compressor, adjusting its speed to optimize cooling efficiency and energy consumption. This component is crucial for maintaining consistent temperatures inside the refrigerator and ensuring smooth, reliable performance.
Causes of a bad compressor inverter board can include electrical surges, overheating, or component failure due to wear and tear. When the inverter board malfunctions, it can lead to inadequate cooling and increased energy usage.
Symptoms of a bad Compressor Inverter Board include:
Took out the old part and replaced it with the new part. Now all is working. Thank you so much. Read more
The Main Control Board Assembly is an OEM replacement part for GE refrigerators. This board controls and monitors all critical functions including temperature regulation and cycle operation. Symptoms of a bad control board include:
Causes can be short circuits, liquid damage to circuitry, or failure of electronic components due to prolonged use. Defects are often not repairable and replacement is necessary. This OEM GE part is also compatible with Hotpoint, RCA, and some Kenmore refrigerator models.
This was a newer GE Monogram side-by-side unit that used an inverter compressor. I removed the inverter and used an ohmmeter to measure the resistance of each of the three windings. They were all very close to one another: about 6.8 ohms per winding. I concluded that the compressor was probably not at fault. The inverter kind of burned or chemical-ish, and, when opened, showed an electrolytic capacitor had burst. I replaced the inverter with an overnight part from Amazon. It was the same... Read more
The Main Control Board Assembly is an OEM part for GE refrigerators. This part manages various functions such as temperature regulation, defrost cycles, and the operation of fans and compressors.
Causes of a bad control board include electrical surges, component wear and tear, or moisture damage.
Symptoms of a bad main control board include:
This OEM GE part is also compatible with Hotpoint, RCA, and some Kenmore models.
Replaced the Main Control Board Assembly along with the evaporator and condenser fan motors. I thoroughly cleaned the very very dirty condenser with a 4$ brush offered by the parts specialist and while I was at it, I changed the door seals and replaced one of the door trays. Beats the crap out of spending $10,000 on a new refrigerator that because of Covid 19 wouldn't be here before the middle of November. Thank you Matt for your help! Read more
The Spring Closure is an OEM part for GE refrigerators. This spring aids in the automatic closing of the refrigerator door, ensuring it seals tightly after each use to maintain optimal internal temperatures.
Causes of a bad spring closure can include regular wear and tear, corrosion due to moisture, or accidental damage that compromises its function.
Symptoms of a bad spring closure include:
1) Remove toe kick panel - 2 Philips head screws 2) Lay down on floor. This might be the hardest part of the repair from some people! 3) Remove broken spring, no tool required. 4) Using your fingers, slip one end of new spring into hole on lever arm. (If you're not sure how it should go, look at the spring on the other door, assuming you have a side-by-side.) 5) Hook the other end of the spring around a round-shank screwdriver. (Don't even bother with pliers. You will disregard this advice... Read more