Tiphliz September 19, 2023 for Model Number FFHS2622MSYA fridge starting acting up since a few power outages.. So I hired a repair guy to come out to fix it.. They came, and required 200 down payment and then never showed up and refuse to answer any of my calls.. So trust issues now... I get the errors, and beeping.. The freezer will maintain its numbers at 9 while the fridge part sometimes stay cold and other time it doesn't.. Its has ice build up, which I have thrawed and removed twice... I have replaced the circuit board.. I am planning to replace the temp sensor that goes through the fridge and other part goes into the freezer.. do you think the temp sensor will be the only thing I need to replace?? Thanks for your time.. Tiph
1 Answer Tiphliz, If the control board has been replaced and the evaporator continues to frost up, this would be more likely that the defrost thermostat is faulty and would need to be replaced.The defrost thermostat would be part number 5303918214. Read More...
Jeff February 21, 2023 for Model Number FFHS2611PFEA I have a frigidaire ffhs2611pfea. I am getting the H1 error on the freezer read out. The coil behind panel in freezer was partially frozen. I thawed it out and retried. It began to freeze up again and errored again. I replaced the defrost thermostat. Was cheap and easy. That did not solve the error code though either. So everything I can research would lead to the thermister? Or the control board. I have the freezer set to 5 and fridge to 5. The temp in freezer is 30 degrees but fridge is 47 to 44 degrees. If I turn up any more I will get error. Just seeing if my research is correct before I order. Compressor is running...
1 Answer Hello Jeff, the HI code refers to the freezer temp too warm, if the compressor, condenser fan, evap fans are running, then likely this is a sealed system problem, either a faulty compressor or a freon leak, a service tech would need to check the ref further at this point. Read More...
Dan October 28, 2022 for Model Number FFHS2611LBK My fridge is too cold (actually freezing) on the lowest setting. The freezer is fine.
Marco September 22, 2022 for Model Number Solutionsbk@live.com I'm getting a H1 error code for the refrigerator side. I checked the evaporator coils and has no ice build up. It's good on freon and i checked both the defrost heater and switch and both are also good. When I checked the damper it was open and not closed. Is this a control problem.
1 Answer Marco, Please resubmit your question with the model number of the refrigerator. Read More...
Scott October 22, 2021 for Model Number ffss2625ts0 i am getting H1 code on both freezer and refrigerator side of display... i believe that error code is an open thermistor.. but both sides going out at once leads me to believe it is a control board
1 Answer Scott, the error H1 is going to indicate a high temperature in the unit. It would be recommended that the evaporator is inspected to identify if it has become blocked up with ice or if there is very little Frost on the evaporator. If there is an ice block, there is a defrost failure that would need to be addressed. If there is less than half of the evaporator covered in a light frost coat and the compressor has been operating for more than an hour, the condenser coils are clogged up with dust or there is a sealed system failure. A sealed system failure would require an EPA-certified technician to diagnose and repair. Read More...
Harold June 12, 2021 for Model Number FFHS2611PFAA This is a side-by-side refrigerator. The freezer is getting cold. The refrigerator is going off/on heat. The condenser fan motor works, the compressor works. I changed out the control board, did a test by sheet everything came out ok but ff still going off on heat, going to check the evaporator coil tonight. Is there anything else that needs to be looked at? I am lost. All food has gone bad please help thank you
1 Answer Harold, it would be recommended that the return duct and the air damper 242303001 are inspected for any blockages and that the damper is opening. If the freezer is reaching the proper temperature as verified by a thermometer, the evaporator and the fans are working properly. This would indicate an airflow issue or a temperature sensing issue with the thermistor 242278801. Read More...
Carlos May 26, 2021 for Model Number FFSS2615TS The Fridge constantly stays running and when you try to turn it off on the panel it starts beeping then turns back on everytime you try to turn it off, so it will not defrost so i have to unplug the fridge will this part fix my problem.
1 Answer Carlos, based on the information provided, the electronic control A01078804 would be the most likely cause of failure. Read More...
Timothy May 05, 2021 for Model Number LFSS2612TE2 The unit shows H1 code for both areas and have frost on the condenser cover in the freezer. After I unplug the unit for several hours the unit runs fine for a couple weeks then the same issue happens. It appears to not be going into the defrost cycle on its own. I am suspecting it may be the control board?? Any ideas??
1 Answer Timothy, after the unit has ran for a couple of hours, it would be recommended that the defrost heater 242044113 and the defrost thermostat 5303918214 are tested from the main control A01078804 once the power cord is unplugged. At the connection J1, the heater would be tested from the brown wire on pin 9 to the light blue wire on pin 1. The resistance should measure 30 Ohms. The defrost thermostat would then be tested from the light blue wire on pin 1 to the blue wire on pin 7 for continuity. If both tests check good, the failure would be in the main control. If any test fails, the part referenced for the test would need to be replaced. Read More...
John March 31, 2021 for Model Number FFSS2614QS6A Can you help please? The motor on the ice maker continuously rotates in an attempt to dump ice. Water will overfill ice maker tray into ice tub. I've disconnected connections to water pumps until I find the issue. Can you help please? Thank you.
1 Answer John, for the ice maker to continuously operate the harvest mode without stopping, the ice maker 241798231 would need to be replaced. Read More...
Blake February 10, 2021 for Model Number FFHS2611PFEA Freezer was cold but not freezing and getting the H1 error. I have since replaced the defrost thermostat and then the defrost heater and getting the same issue. After searching a little more in these questions, I saw a response that there should be frost on all of the coils. I only get build up on the line running to the coils and the top level of coils and fins. There is no ice or frost build up beyond that. Does this mean an issue with the coolant system and needs an HVAC tech? If so, am I better off just getting a new fridge?
1 Answer Blake, From the description of your issue, it would seem that you have a sealed system issue and you will need an EPA certified technician to complete the system repairs. Read More...