For Whirlpool Control Board (Part Number: OEM18039438)

1 Answer

Jmann, There is really no way to test the display other than checking to make sure that the ribbon connector from the user interface is seated fully with the main control board.

Read More...
Alex for Model Number GEW9250PW1

Hello. On my dryer - Whirlpool Duet, the control lock light lits up on its own and I cannot cancel it by holding the proper button for 3 seconds. I had turned the power off for a day and somehow I was able to turn it off and used the dryer for a day or two, but at some point it went on on its own and I cannot turn it off any more. I tried turning the power of etc but nothing worked. What part do I need to replace? - the control board or the control panel with the buttons? Thanks

1 Answer

Alex, The user interface would be the most likely cause for the unit to turn the lock on by itself and would be part number WP8558753.

Read More...

2 Answers

Hello Brant, You should check the thermal fuse WP3392519. The door switch WPW10318609, belt switch 279782, and centrifugal switch in the motor assembly 279787 should also be checked. I'm sorry but this part WPW10318609 has been discontinued by the manufacturer and no satisfactory substitutions have been provided.

Read More...

2 Answers

Brant, If the thermostats and thermal fuses check ok then yes the main control board would be the most likely cause for the unit to not work.

Read More...

1 Answer

Hello Alex. You will need to test the thermal fuse and the power supply to the unit. If both are good then it sounds like the main board is bad on the unit.

Read More...

1 Answer

Hello Kim. Replace the sensors. If the issue continues, then replace the control board on the unit.

Read More...

1 Answer

Jose, This issue would be more indicative of a relay that simply failed and the control board would need to be replaced.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store