Joe Part #218721106 Start Relay/Overload single unit replaced by #5304410951 (2 piece). Red Wire to Overload; Blue to Terminal 2 on Start relay. How/where do i connect capacitor that used to click into part #218721106?
Answer Joe, A model number would have been a better help. In most cases, when the relay/overload kit replaces a start device, the run capacitor (if used) is installed across the run and start windings of the motor relay. The wires from the capacitor would attach to the terminal #@ with the blue wire and the other wire from the capacitor would attach the terminal #3. basically, as best we can tell. Read More... Answered by AppliancePartsPros.com | Monday, May 6, 2019