James Lackey for Model Number FGGS3045KFE I have the FGGS3045KFE Frigidaire has range that is currently set up for LP. Would you please tell me what orfices I would need to convert back to natural gas? Thank you!
Answer James L, Based on the information provided the orifices for Nat.Gas is surface units 316527504 Orifice, burner, 5K 316527500 Orifice, top burner, 9.5K 316527502 Orifice, top burner, 12K 316527509 Orifice, burner, 18.2K and the broil 316409703 the bake is adjustable and don't forget to flip the cap on the regulator. Read More... Answered by AppliancePartsPros.com | Wednesday, July 8, 2020