Peter L for Model Number fase7073nw2 Dryer runs for 22 min then shuts off.Will turn back on Machine is hot.Vents all clear Mess board Do not say anything but when I run Diagnostic Ck it comes up ef2
Answer Peter, There is no EF2 error showing on the tech sheet for this unit. As for the EF error codes they are for blocked duct, a bad exhaust thermistor, inlet thermistor or a faulty control board. You will want to double check venting from the blower wheel to the outside of the home to make sure that there is no blockage. You can also disconnect the hose from the back of the unit and run a load to see if it still does the same thing, if it does then test the control thermistor and the inlet thermistor for resistance. If they both check ok then the issue will be the control board. Read More... Answered by AppliancePartsPros.com | Monday, November 23, 2015