Hans for Model Number GE JSP26BD1AD My new Control Ovn ERC3B differs a bit from the original control panel; the new one doesn't have a ground terminal but the Broil Relais has an L1A terminal, something the old one doesn't have. Do I isolate the ground wire? What do I do about the L1A?
Answer Hans, The L1 that was connected to L1 on the original board would connect to the L1A on the broil relay. For the ground you would just need to connect it to a ground spot on the unit. Read More... Answered by AppliancePartsPros.com | Tuesday, March 3, 2015