Paul for Model Number TFX24RGD I purchased a defroster control new and I need to know which color code wire to which of the four prongs and their are numbers on the the control. we hooked the unite up and it runs the fan but does not go into a cooling cycle.
Answer Paul, Terminal #1 on the timer should have the neutral wire attached( usually white or orange), terminal #2 should have the wire to the defrost heater/ thermostat(usually blue) terminal #3 Should be the power into the timer from the cold control(usually gray or red) Terminal #4 should be the wire out to the compressor overload(usually red or black). Good Luck and Thanks Read More... Answered by AppliancePartsPros.com | Saturday, July 30, 2011