The Fuse is an OEM part for GE microwaves. It serves as a safety device designed to protect the microwave from excessive current that can cause overheating and potential fire hazards. When the current flowing through the microwave circuit exceeds a certain level, the fuse blows or breaks, cutting off the power to prevent damage or fire.

Common causes for a fuse to blow include power surges, faulty wiring within the appliance, or the use of microwave inappropriate containers that cause sparks. It is essential to address these issues not only to replace the fuse but also to correct the underlying problems to prevent future failures.

Symptoms of a bad fuse include:

  • The microwave suddenly stops working.
  • No signs of power or response even when the microwave door is closed and the start button is pressed.

This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models.

More
$10.55
Compare At:
$12.55
You Save:
$2.00

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Ge Fuse (Part Number: OEM11982195)

View all Questions

Answer

Hello Helen. You most likely have a "high voltage" side malfunction. Transformer, diode, magnetron, Capacitor. You will need to be extremely careful if you decide to test the components with a multi meter, Very high residual voltage is present, so make sure you remove power to the microwave and short across the terminals on the capacitor. The magnetron should have a reading of less than 1 ohm resistance across the two terminals, and an "open" circuit between each terminal and chassis ground. The diode/rectifier should have a resistance reading in one direction only, no resistance, or resistance in both directions indicate a faulty diode. The primary winding on the trans former should read approximately 450 Ohms resistance, the secondary winding should read 80 ohms resistance, and the filament transformer should read 100 ohms resistance. If all the readings are proper and in range, replace the magnetron.

Read More...

Answered by AppliancePartsPros.com   |   Wednesday, October 25, 2017

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store