Kris M. for Model Number wm1832 My pre-wash flows water, but my main wash only flows cold water no hot. I am not getting any error codes. The valves test at the correct resistance. Would this be a valve problem or a board problem?
Answer Hello Kris. This model uses a heater and a thermister 6322FR2046C to determine water temperature. It brings in cold water to fill the tub, but turns on the heater to heat the water up for a hot wash cycle. The valves work different chambers on the dispenser, so cold will come in on a hot cycle to empty the dispenser. Hope this helps. Read More... Answered by AppliancePartsPros.com | Friday, July 1, 2011