Customer Questions and Answers for Board Main Asm by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM17912304
Manufacturer Part Number: WR55X24347

The Main Control Board Assembly is an OEM replacement part for GE refrigerators. It functions as the central processing hub, controlling all automated operations and cycles within the unit. 

Symptoms of an inadequate main board include:

  • Appliance failure to cool or lacking temperature regulation
  • Lights, dispensers, or ice makers not functioning 
  • Appearance of blinking lights or error codes

Causes can be normal wear over time or exposure to moisture. Heavy use may accelerate the deterioration of electronic circuitry.

This GE refrigerator part is also compatible with Hotpoint, RCA, and some Kenmore models.

More
$133.21
Compare At:
$158.52
You Save:
$25.31

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Ge Board Main Asm (Part Number: OEM17912304)

Matthew for Model Number GSHS3KGZBCSS

Hello, what would cause my GE fridge to run fine for 12 hours after power cycling, but then the compressor not coming back on the next day when it needs to re-cool again? I power cycle, and then the compressor runs fine again for 12 more hours. (All dirt and dust have been cleaned off the coils) The fridge works great if I power cycle once per day- just can't get the compressor to automatically come back on, but everything else seems fine?? So basically I need to unplug my fridge in order for my fridge to run and cool for several hours. Once it meets all the setpoints, the compressor turns off as it should. It is just not getting the signal to come back on, and then the temps slowly rise until I power cycle again. Thank you!

1 Answer

Matthew, It would either be the main control board or a start relay on your compressor. Your condenser fan should operate anytime the compressor runs because it uses the same circuit. If the condenser fan runs but the compressor does not then I would replace the start device on your compressor. WR07X10143 If the fan by the compressor does not operate when the unit needs cooling then the main board would need to be replaced. WR55X24347

Read More...

1 Answer

Raymond, This issue will most likely be a main control board that is faulty and will need to be replaced.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store