Douglas S. for Model Number GM915-710 SHUGGE1UC/U12 Ok. I had the drain pump with the 6 blue impeller blades. I ordered AP3996662 along with the recommended connector / Adapter AP5323611 - which is essentially a connector housing that isolates and combines the two connectors so that they don't short out. Does it matter which wire goes on which terminal? One has 2 wires attached to the spade lug, the other has one. The old pump had 4 connections, and although I did take a digital picture - it would not be possible to map the connections because the connectors changed on the pump.
Answer Hello Douglas, Since the pump is an ac motor with only one winding, it is not polarized and it will run just fine being wired either way. You can reverse the wires and since alternating current is applied, it will run the exact same way. Read More... Answered by AppliancePartsPros.com | Tuesday, January 29, 2013