Jean for Model Number FRT18B5JQ2 Hi it's me again,I just removed the inside panel from the freezer and the coil is full of ice.what can I do?
Answer Jean, while there is ice blocking the evaporator coils, use a meter and test the defrost thermostat 5303918202 and heater 240356221 for closed circuits. If the heater and thermostat check OK, replace the defrost timer 215846602 Use a hair dryer or steamer to remove the ice from the evaporator coils. That will keep you going until the replacement part(s) arrive and you can get the refrigerator properly repaired. Read More... Answered by AppliancePartsPros.com | Thursday, February 18, 2016