This is the main electronic control board that manages your appliance's cycles, display, and key functions so the unit responds correctly to user inputs and runs selected programs. What it does:

  • Receives input from the console and sends signals to the motor, valves, heaters and other components
  • Controls cycle timing, display messages and indicator lights
  • Can cause unresponsiveness, incorrect cycles, or error codes when faulty
  • May stop the appliance from starting or cause intermittent operation
What's included: One control board Install notes:
  • Disconnect power before servicing to avoid electrical shock
  • Handle the board carefully and avoid touching circuit traces; use ESD precautions if available
  • Installation typically requires removing the console or rear access panel and unplugging ribbon/connectors

More
$223.95
Compare At:
$266.50
You Save:
$42.55

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Frigidaire Control Board (Electronic Main Control) (Part Number: OEM17846853)

View all Questions

Answer

Hey Lori. I found some information on our Repair forum that may help. Fridgedaire dryer error code E66 error code (door open code)....... Check the door switch first for continuity.......then check thermal limiter on burner chamber these are know for blowing if you exceed length and bends on the exhaust length leaving the house (rule of thumb max 15' and each 90 degree bend takes away 5'). Then check thermal limiter on exhaust near motor.......if all three pass continuity test, ohm check the wires in involved circuit. Last but now least if everything checks out with these items it's going to be the main board these units are known for blowing main boards but check the limiters (2 most models) and harness first and if your exhaust length going out of the house is clogged or excessive in length even the brand spanking new Fridgedaire's DO NOT LIKE EXCESSIVE LENGTH AT ALL WHATSOEVER, i've seen burnt clothes when the unit was running at 190 degrees heat max (Gas) type and cycling properly and this model will cause you a headache. The apartment was brand new and the exhaust had 3 (90) bends within 20 ft with no clogging and it caused problems. I had a customer with a multiple problem unit recently after talking with fridgedaire techs we replaced main board, burner tube, coils, etc etc comes to find out as i said these units are super sensitive to excess lengths in exhaust and can be a headache to figure out why it's burning the flow chamber and clothing sometimes. Read more: http://forum.appliancepartspros.com/dryer-repair/464513-dryer-says-door-open-when-its-closed.html#ixzz2uRA5lOzp'>http://forum.appliancepartspros.com/dryer-repair/464513-dryer-says-door-open-when-its-closed.html#ixzz2uRA5lOzp http://forum.appliancepartspros.com

Read More...

Answered by AppliancePartsPros.com   |   Wednesday, February 26, 2014

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store