Ryan for Model Number FPGS3085KF A customer of our has a Frigidaire Professional FPGS3085KF. They are going back from LP to NG. I have already ordered 4 orifices from APP.com and need 1 more for the mega burner at 17K BTU. In the manual it says I need 16,250 BTU Twin Marked 2 x 146N Orifice. Can you let me know the last part I need? Thanks! Ive already ordered 316527500 316527504 316527513 316527514
Answer Ryan, For the conversion you need 3 of 316527500 for the left front and for 2 orifices on the largest burner, 1 of the 316527504 for right rear,1 of 316527513 for the right rear burner and 1 of 316527514 for the 3rd orifice on the larger burner. The largest burner has 3 orifices which will equate to the btu rating that it calls for. Read More... Answered by AppliancePartsPros.com | Thursday, March 10, 2016