Slam for Model Number GLER341AS2 "Hello Slam. That sounds like a control board issue if the thermostat are testing closed. It sounds like the relay on the control board is bad and you will need to replace the board in the unit." May I have an item number for said control board? Also, I took off the high limit thermostat/fuse (T-O-D60T21). It rattles on the inside when shaken, if that matters.
Answer Hello Slam. Lets test the high limit. Your model does not use the board, so either the timer or the temperature switch will be the culprit. To test the high limit. Use an meter and see when it open and breaks voltage to the heater. The see if it closes and the voltage returns. If not, disconnect the power and test for continuity and see if it reads closed. If so, high limit is bad and needs replaced. If it is opening and closing properly, either the timer, or temperature switch is bad and needs to be replaced on the unit. Read More... Answered by AppliancePartsPros.com | Friday, August 24, 2012