Gabriel M for Model Number GFWN1100L1WW Washer not washing properly. The hot water runs fine but he cold cold trickles in. Two error codes have appeared, E66 (water temp problems) and E22 (fill problem; timed out) I've checked all the filters and nothing is blocked. I was wondering if a malfunctioning inlet valve would affect the temperature reading and VISE VERSA. If so, how can I check the valve using an Ohm reader to see if that is what I'm supposed to replace?
Answer Gabriel, To test the water valve coils you will disconnect the wires to the solenoid and do a resistance reading. The resistance should be 1000 to 1250 ohms at room temperature of 77 degrees. If outside this range then the coils are faulty and would need to be replaced. Read More... Answered by AppliancePartsPros.com | Thursday, March 13, 2014