Ashok for Model Number CSX20ELG Stopped working. Based on guidance I replaced Relay, Defrost Timer. Unit turned on made little Ice and then not cooling at all. Replaced the Capacitor. Not cooling but the small fan next to the Compressor comes on for a minute and then stops (this happened after the Relay and Timer was put in as well). Repeats on short interval. Compressr is luke warm. Inside fans appear to be working as I see air flow comin into the Freezer top entry point. Not cooling. I manually turned the Timer nothing is happening.
Answer Ashok, if the evaporator fan is operating continuously while the compressor and condenser fan are shutting off and turning on, it would be recommended that the voltage to the compressor be tested. If the 120 Volts AC is coming and going, the most likely cause of failure would be the wire harness in the cabin. If this is the case, the wire harness in the cabin is not repairable, unfortunately. Read More... Answered by AppliancePartsPros.com | Friday, February 9, 2024