Jw for Model Number PFCF1NJWABB Hello, I have a GE Profile that will not cool. Condenser fan and lights work but the compressor will not run. When plugged in there is one attempt than nothing. The J15 measured at 8.5 vdc, compressor checked at 7.2 ohm on all three posts. Could not detect 120 vdc on the inverter power supply (orange/black wire connector. Any ideas what would cause that?
Answer Hello JW, there should be 120vac on the orange and brown wires to the inverter, and J15 should be anywhere between 4-12vdc, power output from the inverter to the variable speed 3 phase 240vac compressor cannot be tested with a multimeter, instead if the compressor windings ohm out equally with no opens or grounds, then usually the inverter is replaced before the compressor. The compressor cannot be tested further without a known working inverter. Read More... Answered by AppliancePartsPros.com | Monday, September 27, 2021