Troy After replacing with a brand new spark switch assembly, only two of the igniter are sparking (they were all working prior to parts replacement). Does igniter need to be grounded or some sort ? Can i also switch around igniter connection from the spark module for testing purposes ? What am i missing ? buy new igniter or spark module ? Help
Answer Troy, No, the igniters don't need to be grounded, but the area and the burner have to be clean of all debris and spillover residue as well for the burner bases and caps. Yes you can switch the igniter wires for testing purposes( just label them first, and return them to their original position). The chances are very high that you will need the spark module once you've done your testing. Read More... Answered by AppliancePartsPros.com | Monday, November 17, 2014