Answer Hello Julio, Discontinue the power supply to the unit and pull the ice crusher bin from the unit. Remove the one or two screws from the left side of the auger motor back cover. It will now pivot around toward the right and you will need to unplug the wiring harness. It will now come out so it can be serviced on the table. From here it is pretty much self explanatory. Just keep up with the screws and the locations they will need to be re-installed into. Read More... Answered by AppliancePartsPros.com | Wednesday, February 27, 2013