Ddavis263 for Model Number DPGT750EC1PL I'm getting power to the dryer but the control panel isn't lighting up. I get no response from the power on button. It basically looks and acts like it does when its not plugged in. I've tested the limit switches and safety switches for continuity and they all check out. Do I need a main board?
Answer Hi Ddavis. There are more than one parts to consider before you purchase one. Is the line filter OK? This is part #WE04X10127. Is the control board at fault ? Part # is WE04X10120. Is the control panel at fault? Part # is WE04X10134. You might consider using the diagnostic sheet in the rear of the control panel to help you diagnose the unit. However it all basically powers out from the inverter control board part # is WE04X10120. Thank you. Read More... Answered by AppliancePartsPros.com | Tuesday, September 6, 2011