Rick for Model Number JP939BH18B Error Code 152, after doing some research, I find that I need to replace the temp sensor in the RF burner. I can't find that part, do I have to replace the whole burner assembly?
Answer Rick, You will want to: (1) Check all heater, sensor, and wire harness connectors. Make sure they are tight and secure. Check heater ribbon for possible damage. (2) Measure resistance across the heater ribbon at the heater terminals. Resistance should read from 20-80 Ohms. If it does not, replace the heater and recalibrate the inductive sensors. (3) If fault persists, remove sensor connector from the board and measure RTD resistance. Should read from 1030-1150 Ohms (46°F-102°F).If it does not, replace the heater and recalibrate inductive sensors. (4) If fault persists, replace power board. (5) If fault persists, replace main board and recalibrate inductive sensors. Read More... Answered by AppliancePartsPros.com | Monday, May 12, 2014