Chuck for Model Number Kenmore 795.73133.410 (LG) Compressor is running but temps are pretty warm (45 in fridge and everything in freezer is melting). Evap fans not working. Took them out and put 12 VDC to them and they work fine. Any ideas?
Answer Chuck, the fans would need to be inspected when the door switches are being manually activated as the fans will not operate unless the switches are in the closed positions. If they do not operate this way, the main control EBR79267107 would be the likely cause of failure. If they do start to operate this way, the frost pattern on the evaporators would need to be inspected as there should be a light even coating of frost across the entire evaporator. If there is not an even coating of frost, there would likely be a sealed system failure if the condenser coils are clean. If this is the case, an EPA-certified technician would be needed for diagnosing and repairing this unit. Read More... Answered by AppliancePartsPros.com | Monday, January 3, 2022