Marcus for Model Number RF260BEAESR/AA-0001 I have a RF260BEAESR/AA and the ice maker stopped production. Freezer temp set to -1deg F. There are no error codes on display and the fridge is NOT in ICE OFF mode. Resetting ice maker (hold TEST button 8+ sec) does not start a cycle. Pressing the test button momentarily does not start a ice dump cycle. Both functions worked previously. Previous ice production was functional, albeit very slow. There is no filter installed since water supply is from a RO system. Currently there are cubes in ice tray but maker will not dump. Activating the self diagnostic function (during normal operation) does not display any errors. Suspected ice maker unit failure so replaced unit but problem still persists. Since the original ice maker did operate and now does not and the new unit does not operate I suspect power supply problems on PBA. Do you have suggestions on troubleshooting the PBA: i.e. specific voltages on connector CN90?
Answer Marcus, This issue would most likely be that the control board is not reading the sensor on the icemaker to allow it to cycle. Read More... Answered by AppliancePartsPros.com | Wednesday, February 10, 2016