Wu for Model Number Samsung RS2530BSH/XAA No cooling on both sides. I removed the back cover and evaporator coil cover. It seems both condensor fan and evaporator fan are working. Compressor starts to work as well. I could see frost is built up on evaporator coil but only on left side (3 or 4 inch long) of first row of evaporator coil. What could be the problem? Leaking? Main control board? or sensor? I tried to run the self diagnosis by push both IceType-Filter Reset buttons same time and hold them, the display flash and then I heard beap and then the display went off. I release the button, after a few seconds, the display come back as previous setting without any flash light to indicate if there is error. Thanks a lot for your help.
Answer Wu, With there only being about 3 to 4 inches of frost on one of the coils of the unit, this issue would be either a restriction or a leak in the sealed system. Read More... Answered by AppliancePartsPros.com | Monday, June 29, 2015