Frank for Model Number CPD227 Lower oven will not energize any of the 3 heating elements. Upper oven works fine. Replaced lower oven relay board (62681) and the ERC controller. High temp limit switch appears to be OK. When pressing any lower oven heating function, the "prebake" icon will illuminate. This is followed by the "on" icon. At this point one should hear a relay click as is the case with the upper oven. Do you know what would cause failure of any of the lower oven relays to "click"? I have not replaced the main relay board (92029).
Answer Frank, This issue sounds like it would more than likely be that the lower oven relay board is not getting proper power which would indicate a main relay board issue or a wiring issue. Read More... Answered by AppliancePartsPros.com | Monday, October 23, 2017