Digo for Model Number 40185053010 My Kenmore 40185053010 microwave is not turning on. The fuses had continuity and the door switches appear to be functioning properly. I next tested the four thermostats. But I'm not sure what the normal state for each one is supposed to be. The thermostat above the magnetron DE47-20007B and the one on the top DE47-20060A tested closed. The two behind the control panel, DE47-20034A (left) and DE47-00050C (right), tested open. Do any of the thermostats seem bad? If they are good, what would be the next thing to check? Thank you.
Answer Digo, Only one of the thermostats that are behind the control panel should be in the open state and the other should be closed. Sounds like one of the thermostats needs to be replaced. Read More... Answered by AppliancePartsPros.com | Monday, January 13, 2020