Steve for Model Number WF350ANP/XAA Pre-filling doesn't occur. Subsequent parts of cycle work normally including hot or cold settings. Is pre-fill one part of this valve that has failed, leaving others working? Obviously it is 3 solenoid valves in one....for cold only. (hot is a different valve).
Answer Steve, what you will want to do to ensure that the valve is at fault is test for voltage. If the valve is receiving 120v AC at one of the solenoids (with cold water selected for wash temp) when it should fill, then you have a bad valve, cold water valve is part number DC62-00142G. If there is not 120v AC going to a solenoid on the valve, then you have a bad control DC92-00381K. Read More... Answered by AppliancePartsPros.com | Thursday, January 24, 2019