Samuel for Model Number WSF26C2EXY02 I have this side by side. One day it stopped cooling. The compressor and the condenser fan don't start. I bypass fan separately and compressor plugged in directly and it was running well. I thought it's the relay and capacitor so I bought a 3in1. Relay combo kit. Looks like does the same as before with the old relay, makes a short kick, and doesn't want to start. Do you think can be the control border? I checked the white and red wire the once who enter the compressor and I had 0.3-0.5V on the 200V scale. Feels like it doesn't get power to fire the compressor. The funny thing is when I plugged just the compressor and fan directly was working fine. Usually how many volts I should get from control board on those white and red wire?Thanks Sam L. for Model Number WSF26C2EXY02
Answer Samuel, Based on the information provided it does not sound as if you are getting the voltage from the board, the red and white wires should read 120vac if the board is in the run position. Read More... Answered by AppliancePartsPros.com | Thursday, September 10, 2020