The Defrost Bimetal is an OEM part for Whirlpool refrigerators. It acts as a safety thermostat that monitors and controls the temperature during the defrost cycle. This component ensures that the defrost heater turns off when the evaporator coil reaches a specific temperature, preventing overheating and potential damage.

Causes of failure may include a malfunction due to wear and tear over time, electrical failure, or damage from moisture and ice.  

Symptoms of a bad Defrost Bimetal include:

  • The refrigerator is constantly running without cycling off
  • Frost buildup on the evaporator coils, leading to reduced cooling efficiency
  • The refrigerator or freezer compartment is too warm
  • Unusual fluctuations in refrigerator temperature

This OEM Whirlpool part is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper and some Kenmore models.

More
$31.95
Compare At:
$38.02
You Save:
$6.07

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Defrost Bimetal (Part Number: OEM18027960)

View all Questions

Answer

Hello John. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the back wall of the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

Answered by AppliancePartsPros.com   |   Thursday, November 1, 2012

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store