Rh Factor for Model Number KSCS25INSS01 I have 5.6 Volts DC at red white to red on small clip plug, 120Volts AC at black to white on large AC plug and 9 to 11 ohms post to post at compressor and no grounds. This is is a rough one to figure out. With all the above the compressor still won't run. Please Help!!!!! Thanks again RH
Answer Hello RH Factor. With the voltage good, you will need to replace the compressor. Sometimes compressors can test good, but in reality they are bad. You have the correct power going to it, so you will need to replace the compressor 8201675. Hope this helps. Read More... Answered by AppliancePartsPros.com | Saturday, July 23, 2011