Phil I. for Model Number MSD2458GEQ Freezer has a block of ice over the coils. Replaced Adaptive Defrost Control (ADC) and defrost heater with bi metal (thermostat). Freezer and refrierator is empty. Ice maker works, heater appears to be working, light frost on coils after running 24 hours. Now the new problem is that the compressor and condenser fan runs continuously. Freezer setting on 1. Refrigerator setting on 2.
Answer Hello Phil. Check and make sure the temperature control is located in the correct position after replacing the board 61005988. If so, you will want to check and make sure the condenser coils on the unit are clean. If all of this checks out, you may need to replace the temperature control WP61005516. Hope this helps. Read More... Answered by AppliancePartsPros.com | Friday, July 29, 2011