Carsten for Model Number GR465LXKS0 Got replacement element W10275049 but the wiring connection tabs are different than the original W10823692. Is there a diagram of what each tab should be on the W10275049? By my ohm meter, the large "L" shaped tab should be RED. The problem is that, with the terminal configuration different, the 1A, 1B, etc. are not labeled and in a different location. If you have a diagram of which tab is which (1A, 2A, 1B, 2B) please send it. Thanks
Answer Carsten, the two smaller terminals are going to be terminals 1b and 2b. The L shaped terminal would be terminal 2a and would be where the red wire goes. Read More... Answered by AppliancePartsPros.com | Monday, September 21, 2020