Vince for Model Number GR399LXGQ What should the ohm reading be on the limter and on the element for the front left burner?
Answer Hi Vince. The limiters will read closed (.01 -.5 ohms.). Put together the meter leads as you have the meter scale set on R x 1. What the resistance on the leads will normally read in this range. This is subtracted from the measurement you have if you need to be specific. The element resistance is ohms. Disconnect the 1a and the 1b wire. Then on the center terminal to the one that had the red wire on it you will read between 35-65 ohms. Reconnect the red wire and disconnect the orange wire. Test between the center terminal and the orange wire terminal, the meter should read between 25-55 ohms. 9" element is part # WP8203528. Thank You. Read More... Answered by AppliancePartsPros.com | Wednesday, July 11, 2012