Sal for Model Number MDE6800AYW On control panel, cycles buttons are inoperative. Cycle Time shows code 55. Checked Temperature Control Thermistor and thermal fuse on blower housing, they appear to be closed. Dryer was functioning the day before. What should be checked next, please?
Answer Sal, Based on the information provided I would run the diagnostics to see what other codes may come up. It sounds like you may have a control or user interface board issue. Enter diagnostics: Press Air Fluff and Time (^) - 13 Key Membrane. or Air Fluff and Time (+) - 15 Key Membrane keys for 3 seconds, or until a beep is heard. The machine will now be in Service Mode and “d” will be displayed. Press the Wrinkle Release key to access the Diagnostic Codes. Read More... Answered by AppliancePartsPros.com | Friday, March 26, 2021