Kjk for Model Number JES9800AAB I read over the wire Diagram and also through the Q&A here I connected the wires as I believe were correct and the duel burner does not go on. I DID NOT separate the 2 red wires as I have a single red that I connected on 2 and the double on L2. Tan on 4 Yellow on 4a and single Black on S2 I provided the jumper from P1 to S1. Double black on L1
Answer KJK, Based on the way that you have the wires attached, this is the correct wiring. You will want to check from L1 to L2 if the unit is still not working for 240 vac. If there is proper voltage then test with the switch turned to the on position and check from 4 to 4a for 240 vac. If there is power there then the issue will most likely be in the wiring to the element or the element itself. Read More... Answered by AppliancePartsPros.com | Tuesday, February 10, 2015