Leslie for Model Number 110.29522800 CAN THE THREE CONDUCTOR PLUG BE SHORTED TO LET THE MACHINE DRAIN WHILE GETTING A NEW WASHER LID SWITCH ASSEMBLY.
Answer Leslie, You can run an insulated jumper between the two colored wires to bypass the lid switch. Remember the green is ground so it would be the two other wires. We do not recommend using the washer in this state, only to allow the unit to drain. A jumper could cause heat and damage components or worse. Read More... Answered by AppliancePartsPros.com | Wednesday, January 29, 2020