Dlhord for Model Number WED9600TW0 Whirlpool Duet Steam Dryer is running but not heating. Model # WED9600TW0 1. Ran diagnostic tests 2. Receiving L2 “Low Line Voltage and F22 “Outlet Thermistor Open” 3. No breakers tripped, 240 measured at outlet, 240 at power cord connection 4. Ordered and replaced Dryer thermister after completing test 5. Still getting L2 and F31 6. Ordered and replaced Machine Control Electronics board after completing test 7. Still getting L2 and F31 8. Determined no continuity for the Thermal Cut-Off 9. Slammed on floor as shown on video and after second try getting continuity from the Thermal Cut-Off 10. No more L2 or F31 and dryer is heating once again 11. Dryer running and heating for short time 1 to 2 minutes then stops with flashing F22 12. Tested on different setting and same issue with F22 13. Watched Heater Element heat up go off and heat up again and at that point is when dryer stops and flashing F22 appears. 14. Went ahead and ordered the whirlpool-thermal-cut-off-kit 279973-ap3094323. Replaced both parts and tested again. Tested and still getting F22 as stated above (see #11,12, and 13). Need help with next steps needed. Thanks you in advance for your assistance.
Answer Hello Dlhord. If the thermistor is new, you will need to check the wiring harness on the unit. Read More... Answered by AppliancePartsPros.com | Tuesday, February 18, 2014